Cut-water is available for external volutes only. For internal volutes the cut-water is a result of intersection of spiral and diffuser.
The cut-water can be designed in the Cut-water section:
Inner radius r4 |
Informative, see Inlet r4 is the inlet radius of the volute and/or outlet radius of radial diffusers |
Thickness e |
Thickness of the cut-water at the start of the volute (for compensation) |
Compensation φC |
Angle, above which cut-water correction begins (standard: 270°) |
|
The cut-water does disturb the flow, since the cross-section of the flow is narrowed suddenly by the thickness of the cut-water.
To weaken this negative influence, the cut-water can be corrected. This is achieved by assuming that from the angle φC the inner radius r4 increases linearly to a value of r4+e at the end cross-section of the volute. This results in larger volute cross-sections in this area, so that the narrowing of flow caused by the cut-water becomes less significant.
By clicking on Default, you can return to the standard values for the cut-water. |